MS21141J
J
TABLE I. Fastener Dimensions and Strengths.
J
(a) Maximum diameter of blind head (x) shall not exceed maximum diameter of manufactured head (A).
J (b) Sizes "05" and "06" with "-"are installed with a double action tool. All other sizes are installed with a single action tool. Sizes "U05 and "U06" may be installed with a double or single action tool. See Amendment 3 of MIL-F-8975 for tool selection.
(c) -05, -06, S05, S06, -08, -10, and -12 are inactive for new design after 1 January 91. Use U05, U06, S05 and
S06.
(d) Letter "U" signifies single action fastener without frangible type of locking collar or locking collar cap. "U" and "S" code fasteners in sizes "05" and "06" are color identified green on locking collar, shifting washer, or serrated pin. "S" code fasteners may be supplied with a locking collar cap.
(e) Single digit marking is permissible for grip dash numbers less than 10.
(f) Diameter of serrated pin shall not exceed " D" maximum and may be .002 below " D" minimum, in area "p" only
J (g) Not required on -04 diameter parts.
Source: https://assist.dla.mil 2-- Downloaded: Check the source to verify that this is the current version before use.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business